FIND THE RIGHT ENGINE FOR YOUR NEEDS

There's only one way to describe an Isuzu engine’s performance: Legendary. Search for variable and fixed speed Isuzu industrial engines to suit your application and conditions.

FIND THE RIGHT ENGINE FOR YOUR NEEDS

There's only one way to describe an Isuzu engine’s performance: Legendary. Search for variable and fixed speed Isuzu industrial engines to suit your application and conditions.

FIND THE RIGHT ENGINE FOR YOUR NEEDS

There's only one way to describe an Isuzu engine’s performance: Legendary. Search for variable and fixed speed Isuzu industrial engines to suit your application and conditions.

ENGINE FINDER

FILTER BY

Engine type

Fixed Variable

Power output required (kW)

from to

RPM Required

from to
Swipe for full table
ENGINE FAMILY MODEL DISPLACMENT (LITRES) CYLINDERS CONTINUOUS OUTPUT** (KW @ RPM) STANDBY OUTPUT^ (KW @ RPM) SPECIFIC FUEL CONSUMPTION AT CONTINUOUS RATING 100% (G/KWH) SPECIFIC FUEL CONSUMPTION AT CONTINUOUS RATING 100%* (L/H) SPEC SHEET INSTALLATION DRAWINGS
3CA1 GZG01 0.85 3 6.10 @ 1500 6.70 @ 1500 255 1.86 Spec Sheet DOWNLOAD
2CA1 HZG01 0.57 2 7.40 @ 3000 8.10 @ 3000 282 2.50 Spec Sheet DOWNLOAD
3CB1 GZG01 1.12 3 8.20 @ 1500 9.00 @ 1500 256 2.51 Spec Sheet DOWNLOAD
3CE1 BGZG1 1.64 3 12.30 @ 1500 13.60 @ 1500 240 3.54 Spec Sheet DOWNLOAD
4LE1 NYGV01 2.18 4 19.50 @ 1500 21.80 @ 1500 235 5.49 Spec Sheet DOWNLOAD
4LE1 NYGV02 2.18 4 19.50 @ 1500 21.80 @ 1500 235 5.49 Spec Sheet DOWNLOAD
4LE1 TYGV01 2.18 4 25.00 @ 1500 29.00 @ 1500 244 3.00 Spec Sheet DOWNLOAD
4JG2 PD01 3.06 4 26.00 @ 1500 28.60 @ 1500 260 8.10 Spec Sheet DOWNLOAD
4BG1 PVR 4.30 4 35.70 @ 1500 39.50 @ 1500 214 9.15 Spec Sheet DOWNLOAD
4JG1 TPV 3.06 4 35.70 @ 1500 41.90 @ 1500 220 9.41 Spec Sheet DOWNLOAD
4JJ1 TYGV01 3.00 4 36.00 @ 1500 43.00 @ 1500 212 9.14 Spec Sheet DOWNLOAD
4BG1 TRV 4.30 4 49.20 @ 1500 54.10 @ 1500 235 13.83 Spec Sheet DOWNLOAD
4JJ1 XYGV01 3.00 4 50.00 @ 1500 57.00 @ 1500 213 12.75 Spec Sheet DOWNLOAD
6BG1 TQV 6.49 6 73.10 @ 1500 79.40 @ 1500 239 20.92 Spec Sheet DOWNLOAD
4HK1 XYGV02 5.19 4 97.20 @ 1500 108.00 @ 1500 216 25.14 Spec Sheet DOWNLOAD
6HK1 XYGV02 7.79 6 134.30 @ 1500 167.40 @ 1500 219 35.22 Spec Sheet DOWNLOAD
6UZ1 XYGV01 9.84 6 205.00 @ 1500 228.00 @ 1500 215 52.78 Spec Sheet DOWNLOAD
6WG1 XYGV01 15.68 6 311.30 @ 1500 353.00 @ 1500 213 79.41 Spec Sheet DOWNLOAD
ENGINE FAMILY MODEL DISPLACMENT (LITRES) CYLINDERS RATED OUTPUT (KW @ RPM) SPECIFIC FUEL CONSUMPTION AT CONTINUOUS RATING 100% (G/KWH) SPECIFIC FUEL CONSUMPTION AT CONTINUOUS RATING 100%* (L/H) SPEC SHEET INSTALLATION DRAWINGS
2CA1 AZP01 0.57 2 9.80 @ 3600 323 3.79 Spec Sheet DOWNLOAD
3CA1 AZP01 0.85 3 16.30 @ 3600 286 5.58 Spec Sheet DOWNLOAD
3CB1 CZP01 1.12 3 18.70 @ 3200 292 6.54 Spec Sheet DOWNLOAD
3CB1 CZP02 1.12 3 18.70 @ 3200 292 6.54 Spec Sheet DOWNLOAD
3CB1 CZP03 1.12 3 18.70 @ 3200 292 6.54 Spec Sheet DOWNLOAD
3CB1 CZP04 1.12 3 18.70 @ 3200 292 6.54 Spec Sheet DOWNLOAD
3CE1 BDZP1 1.64 3 26.90 @ 3000 259 8.34 Spec Sheet DOWNLOAD
3CE1 BDZP2 1.64 3 26.90 @ 3000 263 8.47 Spec Sheet DOWNLOAD
3CE1 BDZP3 1.64 3 26.90 @ 3000 259 8.34 Spec Sheet DOWNLOAD
3CE1 BDZP4 1.64 3 26.90 @ 3000 259 8.34 Spec Sheet DOWNLOAD
3CE1 BDZP5 1.64 3 26.90 @ 3000 263 8.47 Spec Sheet DOWNLOAD
3CD1 TBKZP1 1.50 3 29.10 @ 2800 264 9.20 Spec Sheet DOWNLOAD
3CD1 TBKZP2 1.50 3 29.10 @ 2800 264 9.20 Spec Sheet DOWNLOAD
4LE1 NYBW01 2.18 4 35.90 @ 2600 257 11.05 Spec Sheet DOWNLOAD
4LE1 NYBW02 2.18 4 35.90 @ 2600 257 11.05 Spec Sheet DOWNLOAD
4LE1 NYBW03 2.18 4 35.90 @ 2600 257 11.05 Spec Sheet DOWNLOAD
4LE1 NYBW04 2.18 4 35.90 @ 2600 257 11.05 Spec Sheet DOWNLOAD
4LE1 NYBW05 2.18 4 35.90 @ 2600 257 11.05 Spec Sheet DOWNLOAD
4LE2 PW10 2.20 4 39.10 @ 3000 234 10.96 Spec Sheet DOWNLOAD
4LE2 PW11 2.20 4 39.10 @ 3000 234 10.96 Spec Sheet DOWNLOAD
4LE2 PW12 2.20 4 39.10 @ 3000 234 10.96 Spec Sheet DOWNLOAD
4LE2 PW13 2.20 4 39.10 @ 3000 234 10.96 Spec Sheet DOWNLOAD
4LE2 PW15 2.20 4 39.10 @ 3000 234 10.96 Spec Sheet DOWNLOAD
4LE1 TYBW01 2.18 4 45.00 @ 2500 265 14.28 Spec Sheet DOWNLOAD
4JG1 PK 3.10 4 46.20 @ 2600 245 13.57 Spec Sheet DOWNLOAD
4JJ1 TYBW01 3.00 4 61.00 @ 2500 225 16.44 Spec Sheet DOWNLOAD
4JJ1 TYBW02 3.00 4 61.00 @ 2500 225 16.44 Spec Sheet DOWNLOAD
4JB1 TPK01 2.80 4 61.90 @ 3000 257 19.03 Spec Sheet DOWNLOAD
4JG1 TPW01 3.06 4 62.50 @ 2500 245 18.34 Spec Sheet DOWNLOAD
4JG1 TPW03 3.06 4 62.50 @ 2500 245 18.34 Spec Sheet DOWNLOAD
4BG1 PW 4.30 4 66.40 @ 2500 237 18.86 Spec Sheet DOWNLOAD
4BG1 TRW01 4.33 4 72.00 @ 2500 255 21.99 Spec Sheet DOWNLOAD
4BG1 TRW 4.33 4 91.70 @ 2500 253 27.78 Spec Sheet DOWNLOAD
6BG1 QW 6.50 6 93.20 @ 2500 252 28.18 Spec Sheet DOWNLOAD
4JJ1 XYBW01 3.00 4 95.00 @ 2500 207 23.55 Spec Sheet DOWNLOAD
4JJ1 XYBW02 3.00 4 95.00 @ 2500 207 23.55 Spec Sheet DOWNLOAD
4BG1 TCW 4.30 4 102.00 @ 2300 253 30.91 Spec Sheet DOWNLOAD
6BG1 TRW02 6.49 6 121.60 @ 2200 247 35.97 Spec Sheet DOWNLOAD
4HK1 XYBW01 5.19 4 147.00 @ 2100 211 37.15 Spec Sheet DOWNLOAD
4HK1 XYBW02 5.19 4 147.00 @ 2100 211 37.15 Spec Sheet DOWNLOAD
6SD1 TQW 9.84 6 182.00 @ 2000 251 54.74 Spec Sheet DOWNLOAD
6HK1 XYBW02 7.79 6 212.00 @ 2000 214 54.33 Spec Sheet DOWNLOAD
6HK1 XYBW03 7.79 6 212.00 @ 2000 214 54.33 Spec Sheet DOWNLOAD
6UZ1 XYBW01 9.84 6 270.00 @ 1950 214 69.20 Spec Sheet DOWNLOAD
6WG1 XYBW01 15.68 6 397.00 @ 1800 214 101.75 Spec Sheet DOWNLOAD

* Specific fuel consumption based on diesel fuel with a specific gavity of 0.835 kg/m3 at 15 degrees C. Actual figures may vary.

^ The Standby Power Rating is applicable to emergency power applications where power is supplied for the duration of normal power interruption. No sustained overload capability is available for this rating. This rating is only applicable to variable loads with an average load factor of 70 percent over 24 hours of the standby rating and for a maximum of 200 hours of operation per year The standby rating is only applicable to emergency and standby applications where the generator set serves as the back up to the normal utility source. No sustained utility parallel operation is permitted with this rating.

**The Continuous Power Rating is applicable when supplying electric power in lieu of commercially purchased power. The number of allowable operating hours per year is unlimited for variable load applications but is limited for constant load applications.