L Series Industrial Engines

The Isuzu L Series engines feature a unique multi-injection fuel system, class leading power to weight ratio and dependability. The Isuzu L Series has been the first choice with Australian users looking for looking for solutions between 2.0 – 3.0 litres.

L Series Industrial Engines

The Isuzu L Series engines feature a unique multi-injection fuel system, class leading power to weight ratio and dependability. The Isuzu L Series has been the first choice with Australian users looking for looking for solutions between 2.0 – 3.0 litres.

L Series Industrial Engines

The Isuzu L Series engines feature a unique multi-injection fuel system, class leading power to weight ratio and dependability. The Isuzu L Series has been the first choice with Australian users looking for looking for solutions between 2.0 – 3.0 litres.

Engine Overview

 

Type Variable & Fixed
No. of Cylinders 4
Injection System Mechanical
Intake System Naturally Aspirated, Turbo
Displacement [L] 2.18 – 2.20
Bore [mm] 85.0
Stroke [mm] 96.0
Gear Case PTO Available on specific models
Flywheel Housing Rear PlateSAE #4, SAE #5
Flywheel SAE 7.5”, SAE 10"
Voltage [V] 12.0
Starter Capacity [kW] 2.0
Alternator Capacity [A] 20.0 – 50.0
Applied Regulation Tier-4, Interim Tier-4
Dry Weight [kg] 170.0 – 190.0

 

Contact Us

Engine Overview

 

Type Variable & Fixed
No. of Cylinders 4
Injection System Mechanical
Intake System Naturally Aspirated, Turbo
Displacement [L] 2.18 – 2.20
Bore [mm] 85.0
Stroke [mm] 96.0
Gear Case PTO Available on specific models
Flywheel Housing Rear PlateSAE #4, SAE #5
Flywheel SAE 7.5”, SAE 10"
Voltage [V] 12.0
Starter Capacity [kW] 2.0
Alternator Capacity [A] 20.0 – 50.0
Applied Regulation Tier-4, Interim Tier-4
Dry Weight [kg] 170.0 – 190.0

 

Contact Us

Engine Overview

 

Type Variable & Fixed
No. of Cylinders 4
Injection System Mechanical
Intake System Naturally Aspirated, Turbo
Displacement [L] 2.18 – 2.20
Bore [mm] 85.0
Stroke [mm] 96.0
Gear Case PTO Available on specific models
Flywheel Housing Rear PlateSAE #4, SAE #5
Flywheel SAE 7.5”, SAE 10"
Voltage [V] 12.0
Starter Capacity [kW] 2.0
Alternator Capacity [A] 20.0 – 50.0
Applied Regulation Tier-4, Interim Tier-4
Dry Weight [kg] 170.0 – 190.0

 

Contact Us

ENGINE FINDER

FILTER BY

Engine type

Fixed Variable

Power output required (kW)

from to

RPM Required

from to
Swipe for full table
ENGINE FAMILY MODEL DISPLACMENT (LITRES) CYLINDERS CONTINUOUS OUTPUT** (KW @ RPM) STANDBY OUTPUT^ (KW @ RPM) SPECIFIC FUEL CONSUMPTION AT CONTINUOUS RATING 100% (G/KWH) SPECIFIC FUEL CONSUMPTION AT CONTINUOUS RATING 100%* (L/H) SPEC SHEET INSTALLATION DRAWINGS
4LE1 NYGV01 2.18 4 19.50 @ 1500 21.80 @ 1500 235 5.49 Spec Sheet Download
4LE1 NYGV02 2.18 4 19.50 @ 1500 21.80 @ 1500 235 5.49 Spec Sheet Download
4LE1 TYGV01 2.18 4 25.00 @ 1500 29.00 @ 1500 244 3.00 Spec Sheet Download
ENGINE FAMILY MODEL DISPLACMENT (LITRES) CYLINDERS RATED OUTPUT (KW @ RPM) SPECIFIC FUEL CONSUMPTION AT CONTINUOUS RATING 100% (G/KWH) SPECIFIC FUEL CONSUMPTION AT CONTINUOUS RATING 100%* (L/H) SPEC SHEET INSTALLATION DRAWINGS
4LE1 NYBW01 2.18 4 35.90 @ 2600 257 11.05 Spec Sheet Download
4LE1 NYBW02 2.18 4 35.90 @ 2600 257 11.05 Spec Sheet Download
4LE1 NYBW03 2.18 4 35.90 @ 2600 257 11.05 Spec Sheet Download
4LE1 NYBW04 2.18 4 35.90 @ 2600 257 11.05 Spec Sheet Download
4LE1 NYBW05 2.18 4 35.90 @ 2600 257 11.05 Spec Sheet Download
4LE2 PW10 2.20 4 39.10 @ 3000 234 10.96 Spec Sheet Download
4LE2 PW11 2.20 4 39.10 @ 3000 234 10.96 Spec Sheet Download
4LE2 PW12 2.20 4 39.10 @ 3000 234 10.96 Spec Sheet Download
4LE2 PW13 2.20 4 39.10 @ 3000 234 10.96 Spec Sheet Download
4LE2 PW15 2.20 4 39.10 @ 3000 234 10.96 Spec Sheet Download
4LE1 TYBW01 2.18 4 45.00 @ 2500 265 14.28 Spec Sheet Download

* Specific fuel consumption based on diesel fuel with a specific gavity of 0.835 kg/m3 at 15 degrees C. Actual figures may vary.

^ The Standby Power Rating is applicable to emergency power applications where power is supplied for the duration of normal power interruption. No sustained overload capability is available for this rating. This rating is only applicable to variable loads with an average load factor of 70 percent over 24 hours of the standby rating and for a maximum of 200 hours of operation per year The standby rating is only applicable to emergency and standby applications where the generator set serves as the back up to the normal utility source. No sustained utility parallel operation is permitted with this rating.

**The Continuous Power Rating is applicable when supplying electric power in lieu of commercially purchased power. The number of allowable operating hours per year is unlimited for variable load applications but is limited for constant load applications.