Engine Overview

 

Type Variable & Fixed
No. of Cylinders 2 – 3
Injection System Mechanical
Intake System Naturally Aspirated, Turbo
Displacement [L] 0.57 – 1.64
Bore [mm] 70.0 –88.0
Stroke [mm] 74.0 – 90.0
Gear Case PTO Available on specific models
Flywheel Housing Rear Plate SAE #4, SAE #5 Semi SAE: #4, #5, #6
Flywheel SAE 7.5"
Voltage [V] 12.0
Starter Capacity [kW] 1.1 – 1.7
Alternator Capacity [A] 40.0
Applied Regulation Tier-4, Interim Tier-4
Dry Weight [kg] 84.0 – 158.0

 

Contact Us

Engine Overview

 

Type Variable & Fixed
No. of Cylinders 2 – 3
Injection System Mechanical
Intake System Naturally Aspirated, Turbo
Displacement [L] 0.57 – 1.64
Bore [mm] 70.0 –88.0
Stroke [mm] 74.0 – 90.0
Gear Case PTO Available on specific models
Flywheel Housing Rear Plate SAE #4, SAE #5 Semi SAE: #4, #5, #6
Flywheel SAE 7.5"
Voltage [V] 12.0
Starter Capacity [kW] 1.1 – 1.7
Alternator Capacity [A] 40.0
Applied Regulation Tier-4, Interim Tier-4
Dry Weight [kg] 84.0 – 158.0

 

Contact Us

Engine Overview

 

Type Variable & Fixed
No. of Cylinders 2 – 3
Injection System Mechanical
Intake System Naturally Aspirated, Turbo
Displacement [L] 0.57 – 1.64
Bore [mm] 70.0 –88.0
Stroke [mm] 74.0 – 90.0
Gear Case PTO Available on specific models
Flywheel Housing Rear Plate SAE #4, SAE #5 Semi SAE: #4, #5, #6
Flywheel SAE 7.5"
Voltage [V] 12.0
Starter Capacity [kW] 1.1 – 1.7
Alternator Capacity [A] 40.0
Applied Regulation Tier-4, Interim Tier-4
Dry Weight [kg] 84.0 – 158.0

 

Contact Us

ENGINE FINDER

FILTER BY

Engine type

Fixed Variable

Power output required (kW)

from to

RPM Required

from to
Swipe for full table
ENGINE FAMILY MODEL DISPLACMENT (LITRES) CYLINDERS CONTINUOUS OUTPUT** (KW @ RPM) STANDBY OUTPUT^ (KW @ RPM) SPECIFIC FUEL CONSUMPTION AT CONTINUOUS RATING 100% (G/KWH) SPECIFIC FUEL CONSUMPTION AT CONTINUOUS RATING 100%* (L/H) SPEC SHEET INSTALLATION DRAWINGS
3CA1 GZG01 0.85 3 6.10 @ 1500 6.70 @ 1500 255 1.86 Spec Sheet Download
2CA1 HZG01 0.57 2 7.40 @ 3000 8.10 @ 3000 282 2.50 Spec Sheet Download
3CB1 GZG01 1.12 3 8.20 @ 1500 9.00 @ 1500 256 2.51 Spec Sheet Download
3CE1 BGZG1 1.64 3 12.30 @ 1500 13.60 @ 1500 240 3.54 Spec Sheet Download
ENGINE FAMILY MODEL DISPLACMENT (LITRES) CYLINDERS RATED OUTPUT (KW @ RPM) SPECIFIC FUEL CONSUMPTION AT CONTINUOUS RATING 100% (G/KWH) SPECIFIC FUEL CONSUMPTION AT CONTINUOUS RATING 100%* (L/H) SPEC SHEET INSTALLATION DRAWINGS
2CA1 AZP01 0.57 2 9.80 @ 3600 323 3.79 Spec Sheet Download
3CA1 AZP01 0.85 3 16.30 @ 3600 286 5.58 Spec Sheet Download
3CB1 CZP01 1.12 3 18.70 @ 3200 292 6.54 Spec Sheet Download
3CB1 CZP02 1.12 3 18.70 @ 3200 292 6.54 Spec Sheet Download
3CB1 CZP03 1.12 3 18.70 @ 3200 292 6.54 Spec Sheet Download
3CB1 CZP04 1.12 3 18.70 @ 3200 292 6.54 Spec Sheet Download
3CE1 BDZP1 1.64 3 26.90 @ 3000 259 8.34 Spec Sheet Download
3CE1 BDZP2 1.64 3 26.90 @ 3000 263 8.47 Spec Sheet Download
3CE1 BDZP3 1.64 3 26.90 @ 3000 259 8.34 Spec Sheet Download
3CE1 BDZP4 1.64 3 26.90 @ 3000 259 8.34 Spec Sheet Download
3CE1 BDZP5 1.64 3 26.90 @ 3000 263 8.47 Spec Sheet Download
3CD1 TBKZP1 1.50 3 29.10 @ 2800 264 9.20 Spec Sheet Download
3CD1 TBKZP2 1.50 3 29.10 @ 2800 264 9.20 Spec Sheet Download

* Specific fuel consumption based on diesel fuel with a specific gavity of 0.835 kg/m3 at 15 degrees C. Actual figures may vary.

^ The Standby Power Rating is applicable to emergency power applications where power is supplied for the duration of normal power interruption. No sustained overload capability is available for this rating. This rating is only applicable to variable loads with an average load factor of 70 percent over 24 hours of the standby rating and for a maximum of 200 hours of operation per year The standby rating is only applicable to emergency and standby applications where the generator set serves as the back up to the normal utility source. No sustained utility parallel operation is permitted with this rating.

**The Continuous Power Rating is applicable when supplying electric power in lieu of commercially purchased power. The number of allowable operating hours per year is unlimited for variable load applications but is limited for constant load applications.